EURO and FME Plugs and Jacks

 

Euro (PAL, IEC)         

ELECTRICAL

 

MECHANICAL

 

Impedance

75 ohms

Durability

250 mating cycles

Frequency

DC to 1GHz

Cable Retention

Cable breaking strain

VSWR

Not specified

Bodies

Brass, Nickel Plated

Insertion Loss

Not specified

Pins

Brass, Nickel Plated

RF Leakage

Not specified

Contacts

Ph. Bronze, Nickel Plated

Insulation Resistance

10 Gohms Min.

Ferrules

Brass, Nickel Plated

Inner Contact Resistance

5 Mohms Max.

Insulators

Delrin

Outer Contact Resistance

5 Mohms Max.

Locknuts

Brass, Nickel Plated

Working Voltage

500V RMS Max.

Washers

Brass, Nickel Plated

Dielectric Withstanding

4KV DC Max.

Gaskets

Silicon Rubber

Cable Fixing ~ EURO PLUGS and JACKS - Nickel Plated

                  

PART NUMBER

CABLE

FIG.

FIXING METHOD

STRIP DIMS

HEX SIZES

PANEL CUT

EU15-0100-C06

CT100

1

Crimp (F)

S3/022

H9

-

EU15-0059-C06

RG59

1

Crimp (F)

S3/022

H9

-

EU10-0100-C06

CT100

2

Crimp (F)

S3/022

H9

-

EU10-0059-C06

RG59

2

Crimp (F)

S3/022

H9

-

 

FME     

 

ELECTRICAL

 

MECHANICAL

 

Impedance

50 ohms

Durability

500 mating cycles

Frequency

DC to 2GHz

Cable Retention

Cable breaking strain

VSWR

1.31:1 Max.

Bodies

Brass, Nickel Plated

Insertion Loss

0.2dB @ 2GHz

Pins

Brass, Gold Plated

RF Leakage

-55dB @ Min.

Contacts

Ph. Bronze, Gold Plated

Insulation Resistance

5 Gohms Min.

Ferrules

Brass, Nickel Plated

Inner Contact Resistance

1.5 Mohms Max.

Insulators

PTFE or Delrin

Outer Contact Resistance

1.0 Mohms Max.

Locknuts

Brass, Nickel Plated

Working Voltage

250V RMS Max.

Washers

Brass, Nickel Plated

Dielectric Withstanding

500V RMS Max.

Gaskets

Silicon Rubber

 

Cable Fixing ~ FME PLUGS and JACKS - Nickel Plated

                      30.50 max                 28.50 max                   32.10 max

                   

                                                         31.10 max

                  

PART NUMBER

CABLE

FIG.

FIXING METHOD

STRIP DIMS

HEX SIZES

PANEL CUT

FM15-0174-C06

RG174, 188, 316

2

Crimp (A)

S1/023

H2

-

FM15-0400-C06

RG142, 223, 400

1

Crimp (A)

S1/033

H3

-

FM15-0058-C06

RG58, URM43

1

Crimp (A)

S1/033

H3

-

FM10-0174-C06

RG174, 188, 316

4

Crimp (A)

S1/023

H2

-

FM10-0400-C06

RG142, 223, 400

3

Crimp (A)

S1/023

H3

-

FM10-0058-C06

RG58, URM43

3

Crimp (A)

S1/023

H3

-

FM07-0174-C06

RG174, 188, 316

5

Crimp (A)

S1/035

H1

PC3

For details on Fixing Methods and Styles, Strip Dimensions, Crimp Hex Sizes, Panel and PCB layouts, refer to the relevant web pages.

 

For further information or to request a quotation call Sales on 0118 933 3788 or click here to send an e-mail

Back to General Coax Home